NVIDIA AI Infrastructure (NCP-AII)
Get full access to the updated question bank and confidently prepare for your exam.
Vendor
NVIDIA
Certification
AI Infrastructure & Ops
Content
166 Qs
Status
Verified
Updated
19 hours ago
Test the Practice Engine
Experience our interactive testing environment with free demo questions
Premium Bundle
Complete Success Suite
Save $34 Instantly
-
βFull PDF + Interactive Engine Everything you need to pass
-
βAll Advanced Question Types Drag & Drop, Hotspots, Case Studies
-
βPriority 24/7 Expert Support Direct line to certification leads
-
β90 Days Free Priority Updates Stay current as exams change
Success Metric
98.4% Pass Rate
Standard Simulation
Practice Engine
One-Time Payment
-
Web-Based (Zero Install)
-
Real Testing Environment Virtual & Practice Modes
-
Interactive Engine Drag & Drop, Hotspots
-
60 Days Free Updates
Compatible with All Devices
Basic Tier
PDF Study Guide
Digital Access
- β Exam Questions (PDF)
- β Mobile Friendly
- β 60 Days Updates
Verified 34-Question Preview (NCP-AII)
Verified Community
The CertoMetrics Standard.
Recommend the #1 platform for verified NVIDIA certification resources.
Success Network
Help a Colleague Succeed.
Invite a peer to get their own updated NCP-AII prep kit.
Exam Overview
The NVIDIA AI Infrastructure (NCP-AII) certification is a crucial credential for professionals navigating the complex world of modern AI deployments. It validates your expertise in designing, deploying, and managing robust NVIDIA-powered AI infrastructure, from foundational hardware like GPUs and DGX systems to the intricate software ecosystem including CUDA, cuDNN, and the NVIDIA NGC catalog. Achieving this certification demonstrates a deep understanding of the entire AI stack, enabling you to optimize performance, ensure scalability, and streamline MLOps workflows. This specialized knowledge is highly valued, positioning you as a key asset in organizations leveraging AI at scale, accelerating career growth, and ensuring efficient, high-performing AI solutions.
Questions
60
Passing Score
700/1000
Duration
100 Minutes
Difficulty
Intermediate
Level
Associate
Skills Measured
Career Path
Target Roles
Common Questions
Is the material up to date?
Yes. We update our question bank weekly to match the latest NVIDIA standards. You get free updates for 90 days.
What format do I get?
You get instant access to both the **PDF** (for reading) and our **Premium Test Engine** (for exam simulation).
Is there a guarantee?
Absolutely. If you fail the NCP-AII exam using our materials, we offer a full money-back guarantee.
When do I get the download?
Instantly. The download link is available in your dashboard immediately after payment is confirmed.
Free Study Guide Samples
Previewing updated NCP-AII bank (34 Questions).
After updating to a Docker version post 19.03, a data scientist attempts to run a container designed for GPU-accelerated applications with the following command:

This generates the following error (output might differ slightly depending on the specific version):

What will fix the problem?
Correct Option: B
The error indicates that GPU functionality is unavailable because the NVIDIA driver wasn't detected by Docker for the container. For Docker versions 19.03 and later, the native way to expose GPUs to a container is by using the --gpus argument with the docker run command. Adding --gpus all will correctly enable GPU access, assuming the NVIDIA Container Toolkit is installed.
- A is incorrect: DOCA drivers are for NVIDIA DPUs, unrelated to standard GPU containerization issues.
- C is incorrect: The container image (PyTorch) is valid; changing to TensorFlow does not address the GPU detection problem.
- D is incorrect: The error suggests a Docker configuration issue for GPU access, not necessarily a faulty host NVIDIA driver. Reinstalling the driver is a less direct fix than specifying GPU access in the Docker command.
Reference: https://docs.nvidia.com/datacenter/cloud-native/container-toolkit/latest/user-guide.html#docker-cli
A system administrator needs to enable MIG so that the end user can run multiple jobs on an NVIDIA A100 GPU.
What command should be used?
Correct Option: C
β Option C (Correct)
Reasoning: The command nvidia-smi -i 0 -mig 1 correctly enables Multi-Instance GPU (MIG) mode on the NVIDIA A100 GPU with ID 0. The -i flag specifies the GPU, and -mig 1 sets the MIG mode to enabled.
β Why the other choices are incorrect:
- Option A is incorrect:
--a100is not a validnvidia-smioption, nor is-enablemigthe correct flag for enabling MIG mode. - Option B is incorrect: The command syntax
nvidia smiis malformed (missing hyphen), and--enablemigis not the correct parameter to enable MIG. - Option D is incorrect: The command syntax
nvidia -smiis incorrect. The-iflag requires a GPU ID, and "enable" is misplaced in the syntax.
Reference: https://docs.nvidia.com/datacenter/tesla/mig-user-guide/index.html
You are tasked with validating the cooling system for a high-density AI cluster using NVIDIA Blackwell GPUs, which generate up to 120 kW of power per rack. What should you prioritize during validation?
Correct Option: B
β
Option B (Correct)Reasoning: A 120 kW rack represents extreme power density, well beyond typical air-cooling capabilities. Liquid-to-air heat exchangers, often found in rear-door heat exchangers or direct-to-chip liquid cooling loops, are critical for efficiently dissipating such high heat loads from NVIDIA Blackwell GPUs. This confirms the fundamental capability.
β Why the other choices are incorrect:
- Option A is incorrect: While maintaining a low supply air temperature is important, 20Β°C might be overly restrictive for modern GPUs which can operate at higher temperatures. The fundamental capacity to remove 120kW, often via liquid, is more critical than a specific air temperature target.
- Option C is incorrect: Dynamic fan speed control optimizes existing airflow for efficiency, but it doesn't address the core problem of providing sufficient cooling capacity for 120 kW. Optimization is secondary to fundamental capability.
- Option D is incorrect: Validating a cooling system for only 50% of its maximum heat load is inadequate and dangerous. AI clusters frequently experience peak loads, and the system must be verified to handle its full design capacity.
Reference: https://www.nvidia.com/en-us/data-center/dgx-h200/, https://www.ashrae.org/technical-resources/technical-committees/tc-9-9-mission-critical-facilities-technology-space-and-electronic-equipment
A system administrator needs to troubleshoot multiple GPUs in a cluster environment.
Which would be the most efficient tool for this?
Correct Option: D
β
Option D (Correct)Reasoning: NVIDIA Data Center GPU Manager (DCGM) is designed for monitoring and managing NVIDIA GPUs in cluster environments. It provides comprehensive diagnostics, health checks, and metrics across multiple GPUs and nodes, making it the most efficient tool for troubleshooting at scale.
β Why the other choices are incorrect:
- Option A is incorrect: NVIDIA-SMI is excellent for monitoring individual GPUs on a single node but is not efficient for consolidated troubleshooting across multiple nodes in a cluster.
- Option B is incorrect: "GPU Health Analyzer" is a generic term. NVIDIA-DCGM is the specific, official NVIDIA tool for this purpose in data centers.
- Option C is incorrect: VMware Aria Operations is a broad cloud management suite. While it can monitor virtualized infrastructure, it lacks the deep, specialized GPU-centric diagnostics provided by NVIDIA-DCGM for direct hardware troubleshooting.
Reference: https://developer.nvidia.com/dcgm
A system administrator is virtualizing GPUs in VMware vSphere and needs to allocate a vGPU profile from the drop-down menu. There are several options available.
What does βgrid_a100-20cβ mean?
Correct Option: D
Option D correctly identifies "20c" as a 20GB vGPU profile on the NVIDIA A100. NVIDIA's vGPU profile naming convention, such as grid_a100-20c, signifies grid for vGPU, a100 for the GPU model, and -20c representing 20 Gigabytes of frame buffer (GPU memory) allocated to the virtual machine. For A-series GPUs, the 'c' suffix typically denotes GBs of memory. This profile provides a specific allocation of GPU memory and proportional compute resources.
Why the other choices are incorrect:
- Option A is incorrect: The "20c" does not indicate over-commitment. Over-commitment is a general vGPU capability, not specified by this part of the profile name.
- Option B is incorrect: "20c" refers to memory allocation, not the number of virtual machines that can share the GPU.
- Option C is incorrect: "20c" specifies frame buffer size (20GB), not 20 compute cores.
Reference: https://docs.nvidia.com/grid/latest/grid-vgpu-user-guide/index.html
A system administrator wants to check the overall health status for their DGX systems.
What command should be used?
Correct Option: B
β
Option B (Correct)
Reasoning: The nvsm (NVIDIA System Management) command-line interface is specifically designed for NVIDIA DGX systems to monitor the overall health, status, and configuration of the entire system, including GPUs, CPUs, memory, and network. It provides comprehensive diagnostics and health checks.
β Why the other choices are incorrect:
- Option A is incorrect:
lspcilists PCI devices and their properties. It is used for hardware enumeration, not for assessing overall system health status. - Option C is incorrect:
ipmitoolis used for IPMI management, providing access to hardware sensors and logs. While useful for hardware status,nvsmoffers a more integrated and DGX-specific health overview. - Option D is incorrect:
nvidia-smi(NVIDIA System Management Interface) primarily monitors and manages individual NVIDIA GPUs (e.g., utilization, temperature, memory). It does not provide the holistic 'overall health' of a multi-component DGX system.
Reference: https://docs.nvidia.com/dgx/dgx-systems-user-guide/index.html#monitoring-dgx-system
You are validating the networking infrastructure of a distributed GPU cluster used for AI training with InfiniBand networking fabric installed across nodes.
How should you validate node connectivity?
Correct Option: C
ib_read_bw and ib_write_bw are specific InfiniBand perftest tools designed to accurately measure bandwidth and throughput between nodes. These tools are essential for validating the high-performance InfiniBand fabric required for distributed AI training.Options A and B are incorrect because Ethernet is not the primary fabric, and IP address assignment doesn't directly validate InfiniBand performance. Option D is incorrect as it only verifies basic power-on, not connectivity or performance.
Reference: https://docs.nvidia.com/networking/display/MellanoxOFEDv59045LTS/Performance+Testing+Tools
A systems administrator needs to provide an AI workload environment for a developer.
Which profile type should the Administrator choose for vGPU?
Correct Option: A
β
Option A (Correct)
Reasoning: C-series vGPU profiles (Compute vGPU) are specifically designed for compute-intensive workloads like AI/ML, HPC, and data science. They allocate GPU resources optimized for processing large datasets and running complex AI models, making them ideal for an AI developer's environment.
β Why the other choices are incorrect:
- Option B is incorrect: Q-series vGPU profiles (Quadro Virtual Data Center Workstation) are primarily for graphics-intensive professional applications, CAD, and VDI users requiring high-fidelity visuals, not compute-focused AI workloads.
- Option C is incorrect: A-series is a naming convention for NVIDIA GPU hardware (e.g., A100, A40) not a vGPU profile type.
- Option D is incorrect: B-series is not a recognized or standard vGPU profile type in NVIDIA's nomenclature.
Reference: https://docs.nvidia.com/grid/latest/grid-vgpu-user-guide/index.html#vgpu-types
A system administrator boots up a DGX A100 system and needs to check the NVSwitch and NVLink initializations.
What will happen to the NVLink connections during initialization?
Correct Option: A
✅ Option A (Correct)
Reasoning: DGX A100 systems utilize Accelerated Link Initialization (ALI), training NVLinks at the GPU and NVSwitch hardware levels early in the boot process. This initial hardware-level training occurs independently of the NVIDIA kernel driver or the user-space Fabric Manager (FM).
❌ Why the other choices are incorrect:
- Option C is incorrect: NVLink physical connections are trained and enabled at the hardware level during system initialization, prior to the NVIDIA kernel driver being fully loaded. The driver enables software interaction, not initial hardware link training.
- Option D is incorrect: Similar to C, this is incorrect. The NVIDIA kernel driver and Fabric Manager (FM) operate at a higher level, managing and optimizing the NVLink fabric after the initial hardware-level link training is completed during system boot.
Reference: https://docs.nvidia.com/dgx/dgxa100-system-user-guide/index.html
A system administrator installed a new DPU on a system and needs to connect to the RHSIM interface using SSH for the first time.
What IP address should the system administrator connect to?
Correct Option: A
β
Option A (Correct)
Reasoning: The 192.168.100.2/24 IP address is the default management IP for the embedded Arm subsystem (BlueField OS) on NVIDIA DPUs, including for initial SSH access to the RHSIM interface. This specific IP is provisioned by default for out-of-band management.
β Why the other choices are incorrect:
- Option B is incorrect: 10.0.0.1/24 is a generic private IP address range and is not the default for NVIDIA DPU RHSIM interfaces.
- Option C is incorrect: 172.16.0.2/24 is another generic private IP address range, not the default for DPU management access.
- Option D is incorrect: 192.168.1.2/24 is a common default IP for consumer networking equipment, not for NVIDIA DPU management.
Reference: https://docs.nvidia.com/networking/display/BlueFieldDPUCoreOS401/BF-2+DPU+CoreOS+Installation+and+Setup
A system administrator wants to enable vGPU virtualization on a DGX A100 system. What action should be taken first?
Premium Solution Locked
Unlock all 166 answers & explanations
Refer to the image:

Which MAC address should be used by the system administrator as the DPUβs out-of-band management interface MAC address?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator needs to replace a failing GPU.
Which of the following commands should be used to check slot capabilities?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator notices a DGX A100 has lost a power supply, but the system is still operating at full performance.
What is the minimum number of power supplies needed for the system to operate at full redundancy?
Premium Solution Locked
Unlock all 166 answers & explanations
Refer to the exhibit.

Which type of NVIDIA LinkX cable has a teal color code?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator wants to determine if ConnectX ports are configured in Ethernet or InfiniBand modes.
What command should be used?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator is responsible for managing an NVIDIA SuperPOD. The administrator wants to verify that all systems are in a healthy state.
What should the system administrator do?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator needs to check the health of the DGX power supplies.
What command should be used?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator needs to check the status of the RShim driver.
What command should be used?
Premium Solution Locked
Unlock all 166 answers & explanations
During a maintenance window, a system administrator needs to verify the CUDA version installed on the NVIDIA DGX server to ensure compatibility with applications.
Which command could be used in the maintenance script to check the installed CUDA version?
Premium Solution Locked
Unlock all 166 answers & explanations
A data scientist wants to run a PyTorch container on docker using a Multi-Instance GPU (MIG) slice. Based on the requirements, the system administrate suggests using a MIG slice with 2g compute profile and 10GB of GPU memory.
What command should the administrator tell the data scientist to run?
Premium Solution Locked
Unlock all 166 answers & explanations
An InfiniBand administrator needs to run performance benchmarks on new devices added to the fabric.
What tool should be used to check the latency?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator needs to improve the performance of MPI operations and use SHARP.
Which items should be offloaded?
Premium Solution Locked
Unlock all 166 answers & explanations
During the setup of a new GPU cluster, you want to validate the GPUs to ensure they meet performance and reliability standards.
What would demonstrate performance standards are met?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator lost SSH connectivity to a cluster management node. It has been identified that a network is broken.
Which network is it?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator needs to use DCGM-exporter to export GPU metrics to an external system to create interactive dashboards.
What system can the DCGM-exporter use without additional configuration?
Premium Solution Locked
Unlock all 166 answers & explanations
It has been over two weeks since the βibdiagnetβ tool was last used to check the InfiniBand fabric for performance. While running the utility today, the following output was received:

What is the first action that should be taken to further analyze the errors?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator needs to install the NVIDIA Container Toolkit and perform the following actions:
Update apt -
Issue the install command -
Configure the Docker daemon to recognize the NVIDIA Container Runtime
Restart the Docker daemon to complete the installation.
What step should be taken first?
Premium Solution Locked
Unlock all 166 answers & explanations
The system administrator is tasked with updating GPU drivers and needs to check the driver version that is currently running.
Which command should the system administrator use?
Premium Solution Locked
Unlock all 166 answers & explanations
On a DCX, a system administrator needs to monitor PSU, CPU Utilization, GPU Utilization, RAID, and Memory Utilization. What single NVIDIA tool should be used?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator needs to reboot a server in an NVIDIA BasePOD, but is unable to SSH. However, they can log into the BMC.
What network should be installed to make sure the system administrator can power up the server?
Premium Solution Locked
Unlock all 166 answers & explanations
Refer to the exhibit.
What is the longest distance that DAC LinkX 25G-NRZ cables can cover?
Premium Solution Locked
Unlock all 166 answers & explanations
An administrator notices that a server is not collecting telemetry data such as traffic flows, performance faults, and events.
In which network does this information flow?
Premium Solution Locked
Unlock all 166 answers & explanations
A system administrator installed a new GPU. The system has booted but the GPU is not recognized by the OS.
What is likely missing?
Premium Solution Locked
Unlock all 166 answers & explanations
Full Question Bank Locked
You have reached the end of the free study guide preview. Upgrade now to unlock all 166 questions and the full simulation engine.
Customer Reviews
Global Community Feedback
David M.
"The practice engine is incredible. It feels exactly like the real testing environment and helped me build so much confidence."
Sarah J.
"The PDF is very well organized and the explanations for the answers are actually helpful, not just random text."
Michael C.
"I was skeptical, but the content is high quality and definitely worth the price. I passed on my first try!"